Sign In | Join Free | My fazendomedia.com
China ATMARS INDUSTRTY CO., LIMITED logo
ATMARS INDUSTRTY CO., LIMITED
ATMARS INDUSTRTY CO., LIMITED Leading Environmental & Vibration Testing Equipment Manufacturer in China - Since 2001
Active Member

7 Years

Home > Walk in Environmental Test Chamber >

8m³ Walk In Environmental Test Chamber Controlled Temperature Humidity Test

ATMARS INDUSTRTY CO., LIMITED
Contact Now

8m³ Walk In Environmental Test Chamber Controlled Temperature Humidity Test

Brand Name : ATMARS

Model Number : AHW-8 SERIES

Certification : ISO, CE

Place of Origin : Guangdong, China

MOQ : 1 Set

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 15 Sets Per Month

Delivery Time : 30 Working Days

Packaging Details : Wooden Box

Capacity : 8m³

Application : Temperature and/or Humidity Test

Power Supply : 3 Phase, 380V, 50Hz

Product Name : Environmental Room

Contact Now

Environmental Room with Controlled Temperature and Humidity Test

ATW/AHW Configurations:
ATW Series - Temperature only
AHW Series - Temperature and humidity capability

Available in FOUR standard temperature ranges:
Type A: -20℃ to +150℃
Type B: -40℃ to +150℃
Type C: -60℃ to +150℃
Type D: -70℃ to +150℃

Standard humidity range: 20%RH to 98%RH (Optioal lower humidity is available.)

What is a Walk-In Chamber?
Walk-In Chambers from ATMARS serves as an ideal test site for large components, assemblies, and finished products. We manufacture both Panel (modilar) Walk-In Chambers and Solid (welded) Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber. A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation.

Technical Specifications of AHW-8 SERIES Walk-in Environmental Chambers
Performance is based on ambient temperature +20 ℃ or circulating water temperature +25 ℃, empty load no specimen.
Model AHW-8A AHW-8B AHW-8C AHW-8D
T&H Adjustment Mode Smart balanced temperature (humidity) control - BT(H)C
Performance Temperature Range -20℃ to +150℃ -40℃ to +150℃ -60℃ to +150℃ -70℃ to +150℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2.0℃
Temperature Devitaion ±2.0℃
Heat-up Rate (Average) From -20℃ to +150℃ 3℃/min. From -40℃ to +150℃
3℃/min.
From -60℃ to +150℃
3℃/min.
From -70℃ to +150℃
3℃/min.
Cool-down Rate (Average) From +20℃ to -20℃
1℃/min.
From +20℃ to -40℃
1℃/min.
From +20℃ to -60℃
1℃/min.
From +20℃ to -70℃
1℃/min.
Humidity Range 20%RH to 98%RH
Humidity Fluctuation ±2.5%RH
Humidity Deviation ±3.0%RH when Humidity>75%RH;
±5.0%RH when Humidity≤75%RH.
Workspace Volume 8m³
Workspace Dimensions W2000xD2000xH2000mm
Exterior Dimensions W2350xD3850xH2400mm
Material Interior #SUS304 Stainless Steel
Seal Imported silicone seal
Insulation Expanded foam & fiberglass
Exterior Cold-rolled steel with powder coated surface
System Heating Nichrome Resistance Wire Heater
Refrigeration Mechannical Refrigeration System
Humidification Stainless Steel Humidifier (Vapor generator system)
Controller Programmable Touch-screen Controller
Noise Level ≤70dB (A-weighted sound pressure level measured at a distance of 1.0 meter)
Allowable Ambient Conditions Temperature: +5℃ to +35℃;
Relative humidity: ≤85%RH (No condensation);
Air pressure: 86kPa to 106kPa.
Power Supply AC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire
Custom options are available.

Test Standards Conformance
GB/T 10586-2006 Specifications for damp heat chambers
GB/T 10592-2008 Specification for low/high temperature test chambers
GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold
GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat
GB/T 2423.3-2016 Environmental testing—Part 2: Testing method—Test Cab: Damp heat,steady state
GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12h+12h cycle)
GB/T 2423.22-2012 Environmental testing - Part 2: Tests methods - Test N: Change of temperature
GJB 150.3A-2009 Laboratory environmental test methods for military material - Part3: High temperature test
GJB 150.4A-2009 Laboratory environmental test methods for military material - Part4: Low temperature test
GJB 150.9A-2009 Laboratory environmental test methods for military material - Part9: Damp heat test
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-78:2012 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

8m³ Walk In Environmental Test Chamber Controlled Temperature Humidity Test


Product Tags:

walk in humidity chamber

      

walk in stability chamber

      
Best 8m³ Walk In Environmental Test Chamber Controlled Temperature Humidity Test wholesale

8m³ Walk In Environmental Test Chamber Controlled Temperature Humidity Test Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ATMARS INDUSTRTY CO., LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)